Q:

Can you use a main breaker panel as the subpanel?

A:

A standard 100-amp load center can be used as a subpanel, according to electrical-online.com. The neutral bonding jumper, however, must be removed. In a subpanel, the neutral must be completely isolated from the ground. When doing electrical work, the power should always be turned off.

For residential service, the neutral and ground can only be bonded in one location, which must be in the main panel. In most panels, a metal strap or machine screw connects the neutral bus bar to the panel case, or ground. This metal strap or screw must be removed. To make the sub-feed connection, an appropriate size and length cable is run between the main panel and the subpanel. For example, 6-3 NM-B wiring can carry 50 amps at a maximum length of 55 feet. At the main panel, the hot legs of the sub-feed wiring is connected to an appropriate branch circuit breaker, the neutral wire connects to the bus bar and bare grounds to the panel case. At the subpanel end, the hot legs of the sub-feed wiring are connected to an appropriate circuit breaker seated on the panel's hot bus bar. This acts as the subpanel's main breaker via reverse feeding. The bare wire is connected to a case ground lug in the subpanel, and the neutral wire is connected to the isolated neutral bar. Electrical work should always be inspected by a licensed professional.


Is this answer helpful?

Similar Questions

  • Q:

    How do you calculate a breaker in a main panel?

    A:

    The size of circuit breaker in a main panel varies depending upon all of the devices to be supplied by the circuit. The amp load of all devices should be added together, explains The Home Depot. If the load of a device is expressed in watts, divide the value of watts by volts to equal the amps. Circuit breakers are sized to operate at 80 percent of their rated capacity.

    Full Answer >
    Filed Under:
  • Q:

    How do you add a 60 amp breaker in your main electric panel?

    A:

    Adding a new breaker to a home's main electrical panel is relatively easy even for someone with limited electrical experience. With just a flashlight and a screwdriver, you can easily add a 60 amp breaker to an electrical panel in 10 or 15 minutes.

    Full Answer >
    Filed Under:
  • Q:

    Do I have to be a licensed electrician to change a breaker panel?

    A:

    If you are not a licensed electrician, you may need to get a permit from your local municipality to change a breaker panel. A breaker panel, also known as a distribution board or circuit breaker panel, can cause serious damage if it is not handled by an experienced electrician.

    Full Answer >
    Filed Under:
  • Q:

    What size breaker would you use on a washing machine circuit?

    A:

    Electrical code calls for a dedicated 20-amp breaker for the laundry room. This circuit provides sufficient power for the washer and a gas dryer. The code allows more than one outlet on the laundry circuit, but it requires all the outlets to be in the same room. If the laundry room has a sink, any outlets within 6 feet of it must include ground-fault circuit interrupter protection.