How to Clean the Flue on a Gas Furnace
1 Inspect the furnace for signs of clogging. A clogged flue will often cover the exhaust pipe with black, sooty-looking material. If this is present on your flue then you probably have a clogged flue. 2 Check your gas furnace manual for the... Read More »
Source: http://www.ehow.com/how_6046372_clean-flue-gas-furnace.html?ref=T...
How to Vent a Gas Furnace
Measure the distance from your furnace vent outlet to the chimney. Purchase the appropriate size and length of metal vent pipe from your local home improvement store. Purchase enough elbows to make any necessary twists and turns. Identify t... Read More »
Source: http://www.ehow.com/how_5853469_vent-gas-furnace.html?ref=Track2&...
How to Replace a 4-Inch Gas Furnace Flue
Remove the screws from the existing flue pipe with your cordless drill. Pull the sections of pipe apart from each other. Measure the length of each section of pipe, write it down and discard the old pipe. Cut new lengths of pipe at the abov... Read More »
Source: http://www.ehow.com/how_6364312_replace-4_inch-gas-furnace-flue.h...
More Common Questions
Answers to Other Common Questions
To properly vent a gas water heater you should consult the manufactures instructions. Different models vent different ways. The best solution is to have a professional do the work.
Read More »
Source: http://answers.ask.com/Home/Gardening/how_to_properly_vent_a_gas_...
1 Measure the distance from the vent outlet on the furnace to the chimney. Purchase the required length of galvanized duct from your local home improvement store. Purchase enough elbows to account for any turns you must make. 2 Cut an entry...
Read More »
Source: http://www.ehow.com/how_5888147_install-gas-furnace-vents.html?re...
Review your furnace installation manual to figure out the correct size of PVC pipe you need to use. Higher BTU furnaces will use 3-inch PVC pipe, while lower BTU furnaces will use 2-inch PVC pipe. Measure the distance from the furnace vent ...
Read More »
Source: http://www.ehow.com/how_6123183_vent-high-efficiency-gas-furnaces...
Check to ensure the heater is plugged in if it will not turn on. Inspect the outlet to make sure nothing is blocking the hot air from escaping. Check the temperature setting if the heater unit is not heating the room. Turn the temperature s...
Read More »
Source: http://www.ehow.com/how_6573175_troubleshoot-direct-vent-gas-furn...
The vent directs fumes from the gas burning through the flue pipe and safely out of your house. Without this vent, you run the serious risk of carbon monoxide poisoning.
Read More »
Source: http://wiki.answers.com/Q/What_is_vent_for_in_a_furnace_gas_valve
I just had a wood burning whole house stove installed by a pro chimney dude. Within 2 months, the flue pipe for the chimney was leaking smoke into the house. It was leaking at the pipe joints. I went out and bought some muffler repair tape ...
Read More »
Source: http://wiki.answers.com/Q/How_do_i_seal_the_flue_pipe_coming_out_...
The one way I have seen it done is not to measure the concentration of oxygen or hydrocarbons (unburned fuel), but to measure the temperature of the flue gas. If the flue gas is actually at ambient temperature, then the furnace is 100% effi...
Read More »
Source: http://answers.yahoo.com/question/index?qid=20080210214516AAjDaay